Changing out K and G base cylinders
This tutorial will guide you through the process of replacing the cylinder on chairs with either a K base or G base. We will cover both bases, including how to detach the seat, remove and replace the pump, and reassemble the chair. Follow the step-by-step instructions to ensure a smooth replacement.
Steps for Replacing the Cylinder on a K Base:
-
Pump the Chair Fully Up:
- Ensure the chair's pump is pumped all the way up. If it doesn't pump, pull it up manually.
-
Remove the Seat:
- There are four bolts that attach the seat to the base. Use an alternating tapping method on the bolts to loosen them.
- One person should hold the seat while the other taps the bolts until the seat detaches from the base.
-
Inspect the Label:
- Check the label on the bottom of the seat to find the sales order number and chair style/model number. This information is essential for warranty claims.
-
Remove the Old Cylinder:
- Use a 4mm Allen wrench to remove the screws that hold the treadle in place.
- Locate the two nuts at the bottom of the pump, which are typically 13mm (or use a ½-inch socket). Loosen these nuts and remove the pump.
-
Install the New Cylinder:
- Position the new cylinder, making sure the orientation is correct.
- Tighten the screws securely, making sure the treadle is positioned correctly.
-
Reattach the Chair Seat:
- Place the seat back on the chair base, ensuring the pin and notch are aligned.
- This will allow the chair to be pumped easily.
Steps for Replacing the Cylinder on a G Base:
-
Remove the Chair Seat:
- Just like the K base, detach the seat using the same method of tapping on the four bolts.
-
Remove the Old Roll Pin (if necessary):
- If you need to reuse the old roll pin, use a quarter-inch bolt and a hammer to drive it out.
-
Remove the Treadle:
- Use a 4mm Allen wrench to remove the set screws from the treadle. Remove the treadle as you did with the K base.
-
Remove the Pump:
- Use a 6mm Allen wrench to remove the socket head bolts under the pump.
- Once the bolts are removed, the pump can be taken out.
-
Install the New Pump:
- Place the new pump into position and secure it by tightening the bolts back in.
-
Reassemble the Chair:
- Attach the chair seat back onto the base, ensuring it’s aligned correctly. The chair should now be ready for use.
Conclusion: Replacing the cylinder on K and G base chairs is a straightforward task that requires a few basic tools. By following these steps, you can quickly and efficiently replace the cylinder and get your chair back in working order.